{"id":3263,"date":"2026-02-15T06:46:08","date_gmt":"2026-02-15T06:46:08","guid":{"rendered":"https:\/\/rsinsulationboard.com\/?p=3263"},"modified":"2026-04-17T01:11:53","modified_gmt":"2026-04-17T01:11:53","slug":"construction-method-statement-for-etics-external-thermal-insulation-composite-systems","status":"publish","type":"post","link":"https:\/\/rsinsulationboard.com\/id\/construction-method-statement-for-etics-external-thermal-insulation-composite-systems\/","title":{"rendered":"Construction Method Statement for ETICS (External Thermal Insulation Composite Systems)"},"content":{"rendered":"<style>.elementor-3263 .elementor-element.elementor-element-51682ff7{--display:flex;}<\/style>\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"3263\" class=\"elementor elementor-3263\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51682ff7 e-flex e-con-boxed e-con e-parent\" data-id=\"51682ff7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5590954d elementor-widget elementor-widget-text-editor\" data-id=\"5590954d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0<\/p><p><strong><b>I. Project Overview &amp; Material Selection<\/b><\/strong><\/p><p>High-rise buildings impose strict limitations on the fire rating (typically Class A) and dead load of insulation materials.<\/p><p>Commonly Used Materials: Aerogel insulation boards, Rock Wool (Mineral Wool) boards, and granulated thermal insulation mortar.<\/p><p>Core Advantage: Nano-aerogel boards feature an extremely low thermal conductivity . With a thickness only 1\/2 to 1\/3 of traditional materials, they effectively reduce the structural load on high-rises while maximizing interior net space.<\/p><p><strong><b>II. Construction Process &amp; Workflow<\/b><\/strong><\/p><p>Standard workflow for the Thin-Plaster Exterior Insulation System:<\/p><p>Substrate Preparation: Remove oil stains and floating dust from the wall surface. Ensure the flatness is controlled within 4 mm.<\/p><p>Surveying &amp; Setting Out: Mark horizontal control lines and vertical reference lines.<\/p><p>Adhesive Application &amp; Board Installation: Use the &#8220;Strip-and-Point&#8221; method for bonding. The effective bonding area must be\u00a0is recommended). Boards should be installed horizontally from bottom to top with staggered vertical joints.<\/p><p>Mechanical Anchoring (Critical Step): Due to high wind loads on tall structures, mechanical anchors are mandatory for secondary reinforcement.<\/p><p>Quantity Requirements: 6\u20138 units\u00a0for low-rise; 10\u201312 units\u00a0recommended for levels above the 20th floor.<\/p><p>Base Coat &amp; Reinforcing Mesh: Apply the first layer of base coat mortar, embed the alkali-resistant fiberglass mesh, and then apply the final layer of finish mortar.<\/p><p>Exterior Finish Application: Application of coatings, stone-like paint, or dry-hung stone cladding.<\/p><p><strong><b>III. Key Technical Points &amp; Quality Control<\/b><\/strong><\/p><p>Detail &amp; Corner Treatment Corners (Internal\/External): Fiberglass mesh must overlap at corners with an overlap width.<\/p><p>Openings (Doors\/Windows): Diagonal reinforcement mesh must be applied at a\u00a0angle at all four corners of openings to prevent stress-induced cracking.<\/p><p>Safety &amp; Environmental Requirements Wind Speed Limits: Construction is strictly prohibited during winds of Level 5 (Fresh Breeze) and above, or during rainy weather.<\/p><p>Weather Resilience: The system must be engineered to withstand drastic temperature fluctuations typical of high-rise environments to prevent panel detachment (delamination).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>I. Project Overview &amp; Material Selection High-rise buildings impose strict limitations on the fire rating (typically Class A) and dead load of insulation materials. Commonly Used Materials: Aerogel insulation boards, Rock Wool (Mineral Wool) boards, and granulated thermal insulation mortar. Core Advantage: Nano-aerogel boards feature an extremely low thermal conductivity . With a thickness only [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3356,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[25],"tags":[],"class_list":["post-3263","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-guide"],"acf":[],"_links":{"self":[{"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/posts\/3263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/comments?post=3263"}],"version-history":[{"count":14,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/posts\/3263\/revisions"}],"predecessor-version":[{"id":3579,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/posts\/3263\/revisions\/3579"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/media\/3356"}],"wp:attachment":[{"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/media?parent=3263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/categories?post=3263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rsinsulationboard.com\/id\/wp-json\/wp\/v2\/tags?post=3263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}